Industry report Gym August 2026

Hygiene and Water Safety in London Gyms and Leisure Centres

A gym can look clean and still have unmanaged water risk, so surface cleaning and water-system control need separate owners and separate records.

Overview

Gyms and leisure centres combine high-touch equipment, repeated peaks in use, showers, changing rooms and, at some sites, spa pools. These areas need different controls. Surface cleaning deals with sweat, dirt, contamination and presentation. Water hygiene deals with conditions inside water systems that can support the growth of Legionella bacteria and expose people to them. Health and Safety Executive (HSE) guidance treats the water risk as its own management responsibility.2, 3

The most useful point for a facilities manager is simple: a clean shower is not evidence of a controlled water system. Legionella control depends on a risk assessment, competent management, temperature control, attention to stagnant and little-used outlets, monitoring and records.2, 3 Cleaning does not replace the site’s water risk assessment. It is better run as its own controlled process, with evidence that tasks happened and a route for correcting failures.

What’s inside

  • Why a clean shower is not evidence of a controlled water system
  • The numbers: Legionnaires' disease and workplace injury, with what they do and do not show
  • The laws and guidance that apply to a gym or leisure centre
  • Where gym hygiene goes wrong, and what good looks like
  • Eight questions to ask a cleaning provider

The sector in numbers

There is a real limit to the public evidence. We found no reliable, current and freely reusable public figure for UK or London gym membership, visits, sector employment or the number of facilities. Commercial market figures exist, but their reuse terms do not allow them to be republished here, so they are left out.

The public numbers that are available describe risks that apply to anyone running a gym or leisure centre. None of them is a gym-specific figure.

Measure Published figure Scope
Reported legionellosis 472 cases in 2024, which UKHSA gives as a 22.0% decrease compared with 20231 England and Wales, all exposure settings
Confirmed Legionnaires’ disease 463 cases in 20241 England and Wales, all exposure settings
Legionnaires’ disease incidence 0.7 per 100,000 population in 20241 England and Wales
Age profile 296 cases (63.9%) of Legionnaires’ disease were in people aged 60 or over1 England and Wales, all exposure settings
Non-fatal workplace injury 680,000 workers sustained a non-fatal injury in 2024/25, from the Labour Force Survey4 Great Britain, all workplaces
Employer-reported injury 59,219 employee non-fatal injuries reported under RIDDOR in 2024/254 Great Britain, all workplaces
Slips, trips and falls on the same level 30% of RIDDOR-reported non-fatal injuries, the largest single kind of accident in 2024/254 Great Britain, all workplaces

The Legionella figures do not show that any of these cases started in a gym. UKHSA reports 2024 cases by broad exposure category: 239 community cases (51.6%, a group that includes travel within the UK), 203 associated with travel abroad (43.8%) and 21 healthcare-associated (4.5%).1 They show why water-system control stays an operating issue, not why any one site is at risk.

The injury figures are not gym injury rates either. HSE states that employers substantially under-report these injuries (overall reporting is around half), so 59,219 is not the true number.4 The share of slips and falls is still relevant to anyone cleaning wet changing rooms and showers.

With no public membership or footfall figure, a site’s own entry records, class bookings and peak occupancy are a better guide to where cleaning hours should fall than a market estimate.

What is changing

HSE’s second edition of HSG274 did not rewrite the hot and cold water guidance. The Part 2 publication is labelled “Second edition 2024”, and carries a note that the second edition has been reviewed and updated in Part 1 only, which covers evaporative cooling systems.2 A new edition date should not be read as a wholesale change to the guidance on hot and cold water systems.

Low-use outlets need active management. UKHSA’s guidance for organisations on a safe water supply, updated 22 January 2025, lists gyms and sports clubs among those who need to take action. It says a potential health risk relates to Legionella in water systems that have had low usage, and that regular flushing of the premises water system is required throughout a period of low usage.11 HSE’s Part 2 guidance says that where outlets are not in regular use, weekly flushing for several minutes can significantly reduce the risk of Legionella proliferation. Once started, the procedure has to be sustained and logged, because lapses can cause a critical increase in Legionella at the outlet.2 The frequency for a site is a matter for its risk assessment.

Workplace waste arrangements have changed. Since 31 March 2025, workplaces in England must separate dry recyclables, food waste and non-recyclable waste before collection. Businesses with fewer than 10 full-time equivalent employees, counted across the whole business, have until 31 March 2027. The Environment Agency can issue compliance notices.10 For a leisure facility, cleaning routines, bins, waste stores and collections have to work with the required separation rather than treating collected material as one stream.

Standards and regulation

Several overlapping regimes apply. They work as a control system, not as interchangeable pieces of paperwork.

Law or guidance Who enforces it What it asks of the person running the site
Health and Safety at Work etc. Act 1974, sections 2 and 35 For non-domestic premises whose main activity falls within Schedule 1 of the Health and Safety (Enforcing Authority) Regulations 1998, the local authority. Schedule 1, paragraph 9 covers “sports, games, entertainment or other cultural or recreational activities”. The Regulations contain further allocation rules, so a site should confirm its own enforcing authority.8 Employers must ensure, so far as is reasonably practicable, the health, safety and welfare at work of their employees. They must also conduct their undertaking so that people who are not their employees are not exposed to risks to their health or safety, so far as is reasonably practicable.
Workplace (Health, Safety and Welfare) Regulations 1992, regulations 9 and 216 The enforcing authority for the premises.8 Every workplace and its furniture, furnishings and fittings must be kept sufficiently clean. Washing facilities, including showers where required, must be suitable and sufficient, and they and the rooms containing them must be kept in a clean and orderly condition.
Control of Substances Hazardous to Health Regulations 2002 (COSHH), regulations 6, 7 and 127 The enforcing authority for the premises.8 Assess the risk from hazardous substances. Exposure must be prevented or, where that is not reasonably practicable, adequately controlled. Employees must receive adequate information, instruction and training. This includes cleaning products.
HSE L8 (Approved Code of Practice, fourth edition, 2013) and HSG274 Part 22, 3 HSE or the local authority, depending on who enforces health and safety at the premises.8 Dutyholders should identify and assess Legionella risk, manage the precautions, appoint a competent person and keep records. HSG274 Part 2 gives the technical guidance for hot and cold water systems.
Regulatory Reform (Fire Safety) Order 2005, articles 9, 14 and 259 Usually the fire and rescue authority, with the exceptions listed in article 25. The responsible person must make a suitable and sufficient assessment of fire risks. Where necessary to safeguard the safety of relevant persons, routes to emergency exits and the exits themselves must be kept clear at all times.
Simpler recycling: workplace recycling in England10 Environment Agency. Separate dry recyclables, food waste and non-recyclable waste before collection, with the micro-firm transition to 31 March 2027.

HSE’s guidance on hot and cold water systems says cold water systems should, where possible, be kept below 20 °C. Hot water should be stored at 60 °C or above and distributed so that it reaches 50 °C (55 °C in healthcare premises) within one minute at the outlets.2 These are water-system control temperatures for the dutyholder, not cleaning temperatures.

Part 2 also says consideration should be given to removing infrequently used showers and taps, and cutting back the redundant supply pipework. Where low-use outlets stay, it describes regular flushing.2 Its example monitoring schedule lists showers and spray taps for removable parts, heads, inserts and hoses to be dismantled, cleaned and descaled quarterly, or as indicated by the rate of fouling or other risk factors.2 This is an example schedule in guidance, and the frequency for a site comes from its own risk assessment.

If a leisure centre operates a spa pool, HSE publishes separate guidance, HSG282, on the control of Legionella and other infectious agents in spa-pool systems.12 A surface-cleaning schedule for the surrounding wet area does not stand in for the spa’s own water treatment and management controls.

Where sites in this sector go wrong

We found no reliable public dataset of gym hygiene inspection failures in London. The points below are failure modes drawn from the law and guidance above, not measured rates.

Treating appearance as water safety. Clean tiles and bright shower fittings do not show that temperature, stagnation or conditions inside the pipework are under control. L8 asks for the Legionella risk to be assessed and managed, and HSG274 sets out the technical controls.2, 3

Leaving little-used outlets stagnant. HSE addresses infrequently used showers and taps, including removal where appropriate and sustained, logged flushing where they remain. UKHSA’s safe water guidance names gyms among the organisations that need to act on low-use water systems.2, 11

Letting shower fittings foul between maintenance cycles. HSG274’s example schedule calls for showerheads and hoses to be dismantled, cleaned and descaled quarterly, or at the frequency the rate of fouling and risk call for.2 Creating a slip risk while solving a cleaning problem. Slips, trips and falls on the same level made up 30% of RIDDOR-reported non-fatal injuries in Great Britain in 2024/25, across all workplaces, and HSE says injuries are substantially under-reported.4 Wet-area cleaning needs a method for controlling access, water and drying, not only a warning sign left beside a large area.

Treating chemicals as a purchasing choice, not an exposure risk. COSHH requires assessment and then prevention or adequate control of exposure, with information, instruction and training for employees.7 The test is whether the products actually on site match the assessment, the method and the training records.

Letting trolleys, waste or stock block escape routes. Where necessary to safeguard relevant persons, the Fire Safety Order requires routes to emergency exits and the exits themselves to be kept clear at all times.9 Cleaning equipment and temporary waste stores need to fit that during the shift, not only after it.

What good looks like

A site manager can use this as a working check.

  • Separate surface hygiene from water hygiene. Give the Legionella risk assessment and control scheme a named owner. Do not assume that shower cleaning meets the water-safety duty.2, 3
  • Verify temperature and stagnation controls. HSG274 Part 2 gives cold water below 20 °C where possible, hot water stored at 60 °C or above, and 50 °C within one minute at outlets, alongside action on low-use outlets.2
  • Control infrequently used showers and taps. Where flushing is part of the risk assessment, make sure the regime is sustained and logged. Agree who carries out and records showerhead and hose cleaning and descaling.2
  • Match cleaning effort to actual use. Use entries, class bookings and local observation to find the peaks, then write down frequencies for equipment, floors, toilets, changing rooms and showers.
  • Control cleaning chemicals under COSHH. Assess hazardous products, control exposure, keep the information available and train staff for the tasks they do.7
  • Build slip prevention into wet-area methods. Keep wet work to areas that can be controlled, manage access and return floors to safe use promptly.4
  • Keep escape routes usable throughout the cleaning shift and align waste handling with the site’s recycling arrangement.9, 10

How to judge a cleaning provider for this sector

Question to ask What a good answer sounds like
How will you turn our opening hours and usage into a cleaning plan? The provider asks for occupancy, class and changing-room patterns, divides the building into zones, and sets written tasks and frequencies instead of one timetable for everywhere.
How do you prove scheduled work happened? There is a record of completion, exceptions, failed checks and corrective actions, with a named owner for unresolved work.
How do your cleaners fit into our Legionella controls? The provider does not claim that cleaning replaces the site’s Legionella risk assessment. It explains any agreed showerhead or flushing tasks, records them, and reports water-system defects to the responsible person.2, 3
How do you control chemicals? Products used on site are covered by a COSHH assessment, methods address exposure, dilution and storage, and information and training are available.7
How do you manage a busy shower or changing room safely? The method keeps wet work to controllable areas, considers people moving through, manages drying, and has a clear response to spills and standing water.4
How do you check shower fittings and wet areas? Surface-cleaning checks are kept separate from the water-hygiene programme. Where descaling showerheads is part of the site’s Legionella scheme, the frequency and record match that scheme.2
What happens when an audit fails? The defect is recorded, someone is made responsible, corrective action is set, and closure is checked, rather than relying on an undocumented re-clean.
How do cleaning operations interact with fire routes and waste separation? Trolleys, supplies and waste do not block required escape routes, and collection routines follow the site’s recycling arrangement.9, 10

How Bayleaf FM approaches this

Bayleaf FM cleans gyms, fitness centres and studios across London, covering the gym floor and equipment, studios, reception, changing rooms, showers and washrooms. The work is planned around the site’s opening hours. Areas are audited zone by zone, and each problem is logged with who has it and the day it was put right. The risk assessments, COSHH data sheets for cleaning products and cleaning team training records are kept in Bayleaf Compliance.

This report gives general information about published law and guidance. It is not legal advice.

Sources

  1. UK Health Security Agency, Legionellosis in residents of England and Wales: 2024, 20 November 2025. gov.uk. Open Government Licence v3.0.
  2. Health and Safety Executive, Legionnaires’ disease. Technical guidance. Part 2: The control of legionella bacteria in hot and cold water systems (HSG274 Part 2), second edition, 2024, paragraphs 2.6, 2.77 and 2.78 and the monitoring table for showers and spray taps. hse.gov.uk. Open Government Licence v3.0, as stated in the publication.
  3. Health and Safety Executive, Legionnaires’ disease. The control of legionella bacteria in water systems (L8, Approved Code of Practice and guidance), fourth edition, 2013. hse.gov.uk and hse.gov.uk. Open Government Licence v3.0.
  4. Health and Safety Executive, Non-fatal injuries at work in Great Britain, updated 7 January 2026. hse.gov.uk. Open Government Licence v3.0.
  5. Health and Safety at Work etc. Act 1974, sections 2 and 3. legislation.gov.uk. Crown copyright, Open Government Licence v3.0.
  6. Workplace (Health, Safety and Welfare) Regulations 1992, regulations 9 and 21. legislation.gov.uk. Crown copyright, Open Government Licence v3.0.
  7. Control of Substances Hazardous to Health Regulations 2002, regulations 6, 7 and 12. legislation.gov.uk. Crown copyright, Open Government Licence v3.0.
  8. Health and Safety (Enforcing Authority) Regulations 1998, regulation 3 and Schedule 1, paragraph 9. legislation.gov.uk. Crown copyright, Open Government Licence v3.0.
  9. Regulatory Reform (Fire Safety) Order 2005, articles 9, 14 and 25. legislation.gov.uk. Crown copyright, Open Government Licence v3.0.
  10. Department for Environment, Food & Rural Affairs, Simpler recycling: workplace recycling in England, last updated 3 October 2025. gov.uk. Open Government Licence v3.0.
  11. UK Health Security Agency, A safe water supply: information for all organisations, updated 22 January 2025. gov.uk. Open Government Licence v3.0.
  12. Health and Safety Executive, Control of legionella and other infectious agents in spa-pool systems (HSG282), January 2017. hse.gov.uk. Open Government Licence v3.0.